Failure to understand the principles appropriate to a particular roof makes it all too easy to introduce condensation problems, often serious ones. A distinction between surface condensation and interstitial condensation is made. Before attempting work on any roof it is necessary to determine how the roof is designed to work. If the principles are wrong, the whole design should be checked and if necessary corrected.
Draughtproofing the windows and external doors of UK dwellings can be an effective and relatively inexpensive means of comfort and reducing heat loss by natural ventilation. In most situations, draughtproofing is unlikely tocause any deterioration in the quality of indoor air. There are however a number of simple checks which should be made prior to installation to ensure that the ventilation requirements of the dwelling and its occupants are satisfied.
The objective of this research is to obtain a correlation between air and sound leakages through slits. Audible sound, in the frequency range from 160 to 8000 Hz, is provided and sound pressure levels on both sides of the considered slit are detected by microphones, so that sound transmission losses can be obtained. Simultaneously, the air leakage through the slit under an inside-outside pressure difference of 50 Pa is also measured.
Points out that increased thermal insulation and draughtproofing of homes can increase the risk to health of indoor air pollution. Includes condensation as a pollutant along with associated mould growth. Notes collaboration by Pilkington the glass company and the Timber Research and Development Association plus Laing the housebuilding group, to combat condensation by passive ventilation. Treats sources of indoor air pollution - formaldehyde, asbestos, gas appliances, tobacco smoke, thoron, radon.
Measurements of the levels of nitric oxide and nitrogen dioxide emitted by radiant and convective space heaters revealed that the NOx emitted by the former was mainly NO2 while convective heaters produced mostly NO. As the air became vitiated, however, the convective heaters began to produce more NO2than NO. This evidence confirms that the nature of the NOx produced by a nunflued room heater depends on the type of heater and the conditions under which it operates.
Summarises measured data on energy savings from conservation retrofits in existing residential buildings, covering approximately 115 retrofit projects in four general catagories: utility-sponsored conservation programmes;low-income weatheriza
Ventilation and infiltration rates were measured in eight office buildings using an automated tracer-gas measurement system. The buildings range in size from a two-story building with a floor area of about 2000 m2 to a 15-story office building.
Describe tests carried out in an 850-seat auditorium of 4000 m3 to compare the readings of a CO2 indicator for controlling the ventilation air flow with the readings from a Stafa odour indicator. Supplies the results in diagrams and tables and discusses them. Notes the odour indication agrees well with the CO2 indication until a certain point when the CO2 concentration is decreasing. Notes this need not be a drawback.
Describes how multizone tracer gas analysis techniques can provide a complete description of office ventilation. Treats the concept of ventilation effectiveness to characterise internal air distribution. Discusses the measurement of whole building ventilation rates and ventilation effectiveness in mechanically ventilated office buildings.
Describes experiments carried out by the Danish Maritime Institute using data from the Aylesbury experiments of the UK Building Research Establishment. The simulation of the standard rural terrain and the Aylesbury terrain was achieved by mea