Air pollution in Dutch homes. An exploratory study in environmental epidemiology.

Carbon monoxide and nitrogen dioxide were monitored in 12 homes on a real-time basis to determine their transient concentrations, their dispersion through the homes and day-to-day variation in pollutant levels. Kitchen ventilation was determined using sulphur hexafluoride tracer gas, and use of unvented gas appliances was monitored with thermo couples. A week-long measurement programme was undertaken in a wide range of homes to determine the distribution of carbon monoxide, nitrogen dioxide, particulates and organic compounds.

The Pennyland project.

Final report on the performance of 177 low-energy houses at Pennyland, Milton Keynes, UK. Pressurization tests showed an air change rate of 0.3 ach for the Pennyland houses, compared to 0.7 ach for the control Neath Hill houses. Three quarters of the houses had some condensation and over a half had some mould growth.

Wind-induced internal pressure load of buildings. Belastung von gebauden durch den windinduzierten innendruck.

The mean and dynamic internal and external pressures of an existing building (tennis hall) and a model of the building were measured and compared. Asystematic examination was made of the effects on wind-induced internal pressure in simple geometric models of flow profile, wind direction, building dimensions, openings and leakiness. Suggestions are proposed for changes to DIN 1055 Part 4. The Canadian, American, British and Swiss Standards on wind loads are compared.

Fifth annual report on the Alberta home heating research facility: results of the 1983-84 heating season.

The Alberta Home Heating Facility has been used over a five year period to attempt to understand the effects of retrofit procedures on the house structure as a whole. The percentage of total energy attributable toinfiltration is calculated, and the influence of furnaces on natural infiltration rates is discussed. Results of blower tests are given for the six modules and compared with measured infiltration rates.

Indoor air quality, infiltration and ventilation in residential buildings. Final report.

Sixty houses built with widely different construction practices and located in different areas in upstate New York were monitored for airtightness (using fan pressurization) and integrated radon concentrations in indoor air, household water,

Development of measurement equipment for the determination of indoor climate. Entwicklung eines messgerates zur ermittlung der physikalischen raumklimabedingungen.

Describes automatic equipment for measuring thermal comfort based on resultant surface temperature, convective heat flux density, air temperature and relative humidity. Results obtained in an environmental chamber are presented and evaluated.

Final report on the Alberta home heating research facility: results of the 1981-82 heating season and part of the 1982-83 heating season to January 1983.

This study used a constant concentration tracer gas measurement system to measure the air infiltration rate of three modules simulating residential buildings in Canada. The results obtained were compared with computer predictions.

Naturally ventilated containers for the carriage of hygroscopic cargoes.

Naturally ventilated containers for international transport of hygroscopic commodities are now well established. Both theory and practice show that the greater the vent areas, the wider the range of conditions under which NVCs will succeed, but there are no established values for acceptable areas. Thetheory, conception and utilisation of NVCs are reviewed. Different vent configurations are tested for simulated and for real voyages.

Organic contaminants: a bibiliography.

Contains references and abstracts on laboratory techniques for analyzing formaldehyde, methodologies for identifying and characterizing a wide variety of organic contaminants and selected field studies of organic contaminants inindoor air.

Assessment of dose from indoor pollutants.

Discusses indoor occupancy factors, including window opening habits, opening of internal doors, time spent indoors and patterns of occupancy, for inhabitants of the United Kingdom.