Ackerman M Y, Dale J D, Forest T W, et al.
Year:
1983
Bibliographic info:
Departmental Report Number 34. Edmonton, Canada: University of Alberta, Dept of Mechanical Engineering, 1983. 138p. 53 figs, 14 tabs, 9 refs. #DATE 00:02:1983 in English

This study used a constant concentration tracer gas measurement system to measure the air infiltration rate of three modules simulating residential buildings in Canada. The results obtained were compared with computer predictions.