Light, tight and well-insulated detached houses reduce cost. Latt, tatt och valisolerat sanker smahuskostnaden.

Describes project on experimental housing of a new type built by Swedish manufacturers employing light, timber construction. Good airtightness and careful work results in the lowest total cost. Investigation shows results of profitability of various investments. Illustrates energy balance for housing discussed.

Measurement of hourly infiltration rate and air change rate in the apartment block La Chaumiere. Mesures du taux horaire d'infiltration et de renouvellement de l'air sur l'immeuble La Chaumiere.

Describes the measurement of infiltration and air change rates in one flat in an apartment block containing 24 flats. Gives the general principles of the pressurization method and tracer gas method for measuring air change rate and infiltration rate. In this situation uses N2O as the tracer gas and measures concentrations with an infra-red gas analyser. Measures the effects of opening and sealing windows, and of closing internal doors on the air change rate and air movement in the flat.

Energy-conserving measures in buildings.

Surveys the Danish energy-saving program in the Ministry of Housing 1975-1987. Covers grant schemes, energy conserving measures in public and state buildings from 1975, control schemes for heating installations, and building regulations. Includes as an appendix a copy of the 1982 Act on the Reduction of Energy Consumption in Buildings.

Airflow around buildings.

Describes the major features of air flow around buildings, indicating how wind characteristics and building geometry interact to determine airflow round a house. Outlines work being done by Watson House in this area, mainly concerned with ventilation, flue performance and dispersal of combustion products.

Basic characteristics of low-cost houses in order to reduce the energy consumption for heating.

Describes a project undertaken for the CEC to build low-energy houses according to a particular design methodology, and to verify the efficiency and practical application of this design. Describes general site layout, climatic effects on the site, and design methodology as applied to the houses. Aims to undertake energy audits in each of the houses,including measurements of air temperature, solar radiation, wind speed, "steady state" behaviour and air infiltration.

Low energy houses: some measured energy consumption figures.

Presents space heating and total energy consumption values for a one-year monitoring period for a group of 27 low energy houses in Saskatoon, Saskatchewan, Canada. These have a number of energy conserving features, including air tightness, controlled ventilation, air-to-air heat exchangers, passive solar heating and high insulation levels. The average space heating energy consumption for the 27 houses was 43.7 Kj/sq.m.DD May 1980-May 1981.The total energy consumption for the houses averaged 365 Mj/sq.m. The space heating energy consumption averaged .228 Mj/sq.m.

Experimental determination of air flow in a naturally ventilated room using metabolic carbon dioxide.

Reports on the metabolic CO2 method for ventilation measurement which has been extended from mechanically ventilated rooms to naturally ventilated ones. The analysis, which under some circumstances is also relevant to tracer gas decay measurements, allows assessments of the individual incoming flows of air.

Air pollution in dwellings. Luchtverontreiniging in woningen.

Reviews sources of indoor air pollution, factors which influence pollutant concentration, and health aspects. Reports on investigations into carbon monoxide concentrations in kitchens with geysers. Treats various factors including geyser type, state of maintenance, frequency of use, occupant type, cooking and ventilating behaviour, time and location of measurements etc.Reports nitrogen dioxide concentration measurements in kitchens and livingrooms relating to cooking and smoking.

Natural ventilation through cracks, or should cracks be sealed. Ventileren door kieren of kieren afdichten.

Reports TNO-IMG research into ventilation of houses including the influence of cracks, open windows, weather conditions, occupants' behaviour, pollutants and guidelines. Lists conclusions such as an opened window renews the room air within half an hour. 40% of the occupants open windows for too long, 27%ventilate insufficiently, 25% of the dwellings are air tight, 75% leaky. Ventilation occurs partially through shafts (30%) and cracks (60%).Ventilation rates differ considerably between the rooms in a house.Ventilation ducts should have an exhaust function.

Automatic variable ventilation control systems based on air quality detection.

Mechanical ventilation systems usually provide a fixed quantity of "fresh" air to a building space based upon the maximum number of people expected to occupy that particular space. When the use of a building space is below its design maximum, the amount of outside air brought into that space can be reduced, thus generally also reducing energy consumption through lower heating and cooling loads. One method of determining the necessary ventilation rate for aparticular space is to utilize an air quality detector (eg CO2 or O2) sensitive to building occupancy and activity load.

Pages