Passive Cooling: A Case Study of the Evaporation Phenomena

Passive cooling strategies require strict adherence to the physical world. Ones imagination creates the flow of ideas that can blossom into a comfortable setting, but the reality of design, construction and cooperation has to be observed and accepted. Physical laws govern as natural processes follow the path of least resistance. In order for us to overcome these laws extra energy is required. That is why passive cooling designers must investigate how to create a comfortable setting by understanding how natural procedures work.

Analysis of a ventilated residential building by means of an air based radiative cooling system

The thermal performance of a monozone building located in Lisbon is studied when night ventilation combined with radiative cooling is used in order to remove the heat from indoors. For simulating the thermal behaviour of the building, a commercial energy building software is used. The potential for radiative cooling in Lisbon, as well as the efficiency of the radiative cooling system were investigated previously. A validated numerical model is used in order to predict the temperature of the air at the outlet of the radiative system.

An experimental study of a naturally ventilated cavity wall

Cavity wall is often proposed in the building envelope design as a solution for improving the thermal comfort of the inhabitants and reducing the adverse condensation effects on the building fabric. In order to evaluate the thermal effect of ventilated air gaps on building energy demand and comfort, an experimental ventilated cavity wall has been built and tested. The cavity wall separates two ambients at different temperatures that are assumed to be constant over the time required to perform the experimental analysis.

Annual variation of air distribution in a cold climate

The airflows through a one family prototype building have been simulated. Supply openings in living room and bedrooms have a size of 200 and 400 cm2 respectively. The ventilation system is a passive stack ventilation system, with ventilation chimneys from kitchen, WC and bathroom. The following parameters have been studied: the supply opening areas and heights, the overflow opening areas between bedrooms and hall and between WC/bathroom and hall, the height of the ventilation chimneys and the opening and closing of living room and bedroom doors.

Energy efficient residential ventilation control

A concept is investigated for the energy efficient control of residential mechanical ventilation in response to outdoor air temperature and the corresponding stack-driven infiltration. The control concept takes advantage of the natural air leakage characteristics of a house and the ability of temperature-driven stack infiltration to provide ventilation air to the house. As the outdoor to indoor temperature difference increases and natural infiltration increases, the fan operation is reduced, thereby minimizing over-ventilation.

IEA ECBCS Annex 36 : Energy Concept Adviser for Technical Retrofit Measures - An internet-based Tool on Information, Assessment and Concept Development of Energy-saving Retrofit Strategies

Research partners of 10 different countries are developing a computer tool in the framework of IEA ECBCS Annex 36, which helps decision makers to include the most energy-efficient and economic technical retrofit measures into the retrofit of their educational buildings.

Developing virtual laboratories for the design and test of ventilation control strategies

The control industry integrates more and more recent innovations, especially on the sector of communication networks (bus), control (fuzzy logic, neural networks...) and informatics (hard-and software) for the development of Building Automation and Control Systems of HVAC plants. These complex control strategies are now being implemented on ventilation systems (hybrid systems, mechanical systems, etc) to satisfy energy and environmental issues.

Ventilation characterization of a new manufactured house

A manufactured home has been installed on the NIST campus for ventilation, energy andindoor air quality studies. The primary purposes of the facility are to study mechanicalventilation requirements for U.S. manufactured homes and to investigate the systems used tomeet these requirements. In addition, the building will be used to investigate moisture issues,indoor air quality impacts of combustion appliances, and VOC emissions from buildingmaterials and furnishings. The first phase of this multiyear effort has focused on airtightness,system airflows and air change rates.

Variable zone multipoint analysis in enclosure with turbulent transport properties in advanced thermal energy reduction technique

Many recently developed energy-reducing strategies with respect to heat loads in residential interiorsincluded in simulation programs possess extensive capabilities in handling these loads (gains orsinks) for each zone - spatial unit designed for maintaining moist air thermodynamics there.We have taken up procedure, which was primarily dedicated to the influence of the sensor positionsof a room model.

User "friendly" residential ventilation system control strategies and effectiveness

The most efficient ventilation system would only operate on demand, when ventilation was "needed". Running the ventilation system all the time at a low flow rate, a rate sufficient to match the ASHRAE recommended 0.35 ACH is a crude control approach to an optimum system. Conditions in a house are not constant. On average, a constant flow rate ventilation system will work reasonably well and certainly is simple, but there are more energy efficient approaches, and users tend to shut down systems that run constantly.

Pages