Viljanen M.
Year:
1981
Bibliographic info:
Report 13/1981, Technical Research Centre, Finland.

The first part of the study describes thermography generally as a method for non-destructive testing of a building envelope for thermal and air tightness properties. The study has resulted in a two stage testing method of which pressurizing is an essential part. The field study has shown that thetwo-stage method is suitable in detection of air leakages, showing that the major part of thermal defects in the building envelope are due to air leakages.