Cummings J.B., Withers C., Parker D.
Year:
2007
Bibliographic info:
IAQ Applications, Vol. 8, n° 2, pp 6-8

The conclusions of an earlier research on humidity control in stand-alone houses are first presented in that paper, then a discussion follows on RH control targets , observed RH levels and the levels at which mold growth occurs. Then a second round of experiments are presented, and compared to the previous ones. The performance of 7 humidistat models are examined and a new control stategy is proposed.