Rudd A F, Lstiburek J W
Year:
2000
Bibliographic info:
in: ASHRAE Annual Meeting 2000, proceedings of a conference held Minneapolis, USA, June 24-28, 2000.

Ventilation air change rate, local mean age-of-air, and interzonal ventilation air distribution were measured for two single-family homes and eight ventilation systems. A multizone, single-gas, tracer gas decay measurement technique was used. A single-story, slab-on-grade, 1350 ff house was tested in Las ~gas, Nevada, and a two-story, 3192ft2 house with basement was tested in Minneapolis, Minnesota. The ventilation systems studied included various configurations of exhaust, supply, and balanced ventilation, with and without whole-house recirculation by the central heating and cooling air-handler unit fan. Some of the systems were independent of the central air distribution system, while others were integrated with it. In general, results showed that all ventilation systems benefitted from periodic operation of the central fan, giving excellent uniformity of ventilation air distribution. Systems without central fan recirculation showed poor ventilation air distribution for closed rooms where there was no ventilation system duct.