Luo M
Year:
2001
Bibliographic info:
Hong Kong, City University, Division of Building Science and Technology, 2001, proceedings of IAQVEC 2001, "Indoor Air Quality, Ventilation and Energy Conservation in Buildings: Fourth International Conference", held Changsha, Hunan, China, 2-5 October, 2

In modern buildings, smoke control systems are integrated into the air supply systems. It is possible that the design of the smoke control system will dominate the design process of the air supply system. Smoke reservoir size is one of the design parameters for the smoke control system. The reservoir size has been limited to 2000-3000 m2 in both Hong Kong and UK. However, this study revealed that the smoke reservoir size should be considered in connection with the slab ceiling height of the smoke zone. The higher the slab ceiling, the larger the smoke reservoir could be. The smoke reservoir size could be greater than 3000 m2 if the slab ceiling height is greater than a certain value. This concept has been adopted for various special projects, which the reservoir sizes exceed the prescriptive requirement.