Nozaki, A.; Ichijo, Y.
Year:
2007
Bibliographic info:
The 6th International Conference on Indoor Air Quality, Ventilation & Energy Conservation in Buildings IAQVEC 2007, Oct. 28 - 31 2007, Sendai, Japan

This research determines chemical substance removal rates of domestic air cleaners using with thepollutant constant-emission test. In previous studies, we have already reported the formaldehyderemoval rates of room air cleaners and the high accuracy of our method for predicting indoor pollutantconcentration. In the present study, the VOCs removal rates of room air cleaners were measured.Gas-phase contaminants were supplied to the environmental test-chamber using a custom-builtemission device. And performance evaluation test was conducted to two kinds of air cleaners. Whenthe air cleaner was in operation, there was a marked reduction of VOCs concentration.The results show that the ECAR (or CADR) for ethylbenzene ranged from 57.6 to 210 [m3/h], that form-xylene ranged from 57.2 to 247 [m3/h], and for styrene ranged from 46.1 to 228 [m3/h]. Thecorrespondence rates between measured and predicted concentrations of ethylbenzene, m-xylene andstyrene were 69.7, 71.1 and 66.7 [%], respectively.