Chung K C, Wang W A, Chiang C M
Year:
1997
Bibliographic info:
France, Centre Scientifique et Technique du Batiment, proceedings of the Second International Conference on Buildings and the Environment, held Paris, June 9-12 1997, Volume 1, pp 333-340.

This paper describes the measured and calculated results of air humidity and profiles of tracer gas in a residential apartment in Taipei city, Taiwan. A complete multizone indoor air quality model was used to evaluate the test results. The concentration of C02 were employed to investigate the indoor pollutant transport. Also, the indoor air humidity was studied in order to evaluate the indoor moisture effects on human. The data from the measurements were used as simulation input data for the calculation of indoor air flow rates and pollutant concentrations. The results of comparisons between measurement and simulation values of indoor air humidities and C02 concentrations using the simulated model are reasonable.