Siviour J.B. Mould A.E.
Year:
1977
Bibliographic info:
In "Ventilation and infiltration in dwellings", proceedings of C. I.B. steering group S17 meeting "Heating and climatisation" Holzkirchen September 1977

Describes how ventilation rates in two houses with recirculating air distribution systems were monitored by injecting CO2 tracer gas into the supply and measuring its concentration in the return air. In one house with solid concrete floor, normal windows and air bricks, ventilation rates were mainly dependent on wind speed. In the other with suspended timber floor and weatherstripped windows ventilation rates were much lower and mainly dependent on internal to external temperature difference. This house also had a seasonal difference with ventilation rates in October about one third less than in July