Airbase

AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

Access to the publications is free of charge.

In modem livestock buildings the design of ventilation systems is important in order to obtain good air quality.
Svidt K, Bjerg B
In recent years large glazed spaces has found increased use both in connection with renovation of buildings and as part of new buildings. One of the objectives is to add an architectural element, which combines indoor- and outdoor climate.
Hendriksen O J, Madsen C E, Heiselberg P, Svidt K
The central aim of this project i s to provide knowledge and tools for increasing the energy efficiency and performance of new and existing laboratory-type facilities in California.
Mills E, Bell G, Sartor D, et al
The rainscreen principle is not new. It was proposed as early as the mid sixties by researchers of the Division of Building Research of the National Research Council of Canada and the basic principles were developed.
Quirouette R
The rainscreen principle is not new. It was proposed as early as the mid sixties by researchers of the Division of Building Research of the National Research Council of Canada and the basic principles were developed.
Quirouette R
The rainscreen principle is not new. lt was proposed as early as the mid sixties by researchers of the Division of Building Research of the National Research Council of Canada and the basic principles were developed.
Quirouette R
The purpose of this study was to correlate building envelope performance problems which are currently being experienced in low rise wood frame residential buildings in the coastal climate of the BC Lower Mainland, with sources of moisture, and des
Morrison Hershfield Limited
The fan pressurization method produces a result that characterizes the airtightness of the building envelope or parts thereof.
Anon
This report provides information and advice to policy and decision makers, researchers, architects, designers, and manufacturers on (i) strategies for achieving a satisfactory balance between good indoor air quality (IAQ) and the rational use of e
Baldwin R
In 1987, workers in the kitchen of one of the teaching hospitals in Halifax, Nova Scotia began to experience symptoms of pruritus, folliculitis, wheezing, conjunctiva/ irritation, sore throat and headache, all suggestive of an indoor air quality (
Fox R A, Shires D B, Fox H M, et al
This guide is divided into four sections, which draw together different areas of BRE radon-related research. It supplements existing guidance. Sump systems are usually very effective at reducing indoor radon levels.
Anon
                   
Wietlisbach V, Pope C A, Ackermann-Liebrich U

Pages