AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

Access to the publications is free of charge.

The methods available for the measurement of air infiltration and air movement in large industrial halls are restricted by the size of the building and the nature of the operations which take place within it.
Sutcliffe H, Waters J
This article discusses the application of tracer gas methods to industrial hygiene investigations.
Grot R, Lagus P
This report describes tracer gas measurements of the local mean age of air at different locations within an office room.
White M, Walker R
A "HESCO"-type diffuser was selected as an example for the validation exercise in the IEA Annex 20 project (Air flow pattern within buildings). It consists of 84 small round nozzles that are arranged in four rows in an area of 0.71 m x 0.17 m.
Chen Q, Moser A
A new handbook, describing in details the measurement techniques which could be used to better understand the infiltration and ventilation in buildings is presented.
Roulet C-A, Vandaele L
Airflow rates are directly affected by the amount of open area and consequently by the inhabitant behavior with respect to window opening.
Roulet C-A, Scartezzini J,Cretton P, Fritsch R
Increasing interest is attributed to the problem of the accumulation of organic vapours emitted from indoor building materials due to an effective insulation of buildings with low ventilation rates.
Gehrig R, Affolter M, Hofer P
Within the frame of the IEA Annex 20, laboratory and numerical experiments were conducted in order to study the flow within an isothermal parallepipedic testroom (L x W x H = 4.2 m x 3.6 m x 2.5 m).
Biolley F, Fontaine J, Rapp R, Serieys J
Is it possible to translate a computed flow field to a design case with different physical dimension?
Moser A
The work in this paper contributes to the work in the IEA - Annex 20 "Air Flow Patterns within Buildings" and presents a series of full-scale measurements of the concentration distribution in a room with isothermal mixing ventilation.
Heiselberg P, Bergsoe N
Seen from the AIVC Technotes 21 and 28, Ventilation Efficiency is still a complex concept. As well for measurements as for simulations.
Haghighat F, Bienfait D, Phaff H
The measurements reported in this paper were carried out in a mock up of an office room, ventilated by a commercial supply air terminal consisting of 84 nozzles (characteristic dimension SqRoot of As = 0.0975 m).
Sandberg M, Blomquist C, Mattson M
Zonal models are a promising way to predict air movement, in a room with respect to comfort conditions and gradient of temperature, because they require extremely low computer time and may be therefore rather easily included in multizone air movem
Inard C, Buty D
The present work is an investigation of ground heat exchangers for the air-conditioning of the supply air to residential buildings.
Trümper H, Albers K-J
A new algorithm for the continuous measurement of variable air change rates with tracer gases will be presented. It differs from the constant concentration method by allowing the concentration level to vary according to the air change rate.
Rabenstein R, Heidt F D
The knowledge of IEA-Annex 14 'Condensation and Energy' has been applied to develop a new strategy for humidity control in dwellings. The presented control element assures safe prevention from mould growth at a minimum energy consumption.
Raatschen W
A laboratory investigation has been made in a modern Swedish bathroom continuously ventilated by an exhaust fan. The tests consisted of measurements of the humidity, temperature and local mean-age after a standard shower.
Fransson J
A conference room has been converted to temperature- and carbon dioxide controlled ventilation. A number of tests have been conducted with the system in different load conditions.
Fahlen P, Andersson H
A test programme has been designed to evaluate the performance characteristics of sensors for the automatic control of ventilation rates.
Fahlen P, Ruud S, Andersson H
Demand controlled HVAC-systems have many advantages. The principle is to optimize comfort and to minimize energy consumption simultaneously. In modern office buildings, indoor temperature is very often a useful control parameter.
Braun W