Airbase

AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

Access to the publications is free of charge.

This paper evaluates the suitability of humidity-controlled house ventilation system to determine (i) the effectiveness of relative humidity as a sensing element, and (ii) the operating and performance characteristics of such ventilation strategy.
Parekh A, Riley M
A literature search was performed to gain as much knowledge as was available on ventilation, indoor air quality sensors and demand controlled ventilation (DCV) strategies.
Hamlin T, Cooper K
Field investigations were undertaken on five houses to determine the potential for improved performance and lower costs through the use of a demand controlled ventilation (DCV) systems.
Moffatt P
The performance of a system for demand-controlled ventilation was investigated for a period of 1.5 years. Presence sensors of the passive infrared type are used to control the ventilation rate in each classroom.
Norell L
In Halmstad a multi-apartment house has been built with air carried heating. Fresh air was used as the only heat carrier. To improve the air quality it was decided not to use circulation flow, which is normally required for air carried heating.
Carlsson T
Modern one-family houses in Scandinavia are often ventilated by an exhaust fan. Most of the outdoor air probably enters through whatever cracks and openings there are and only a small part enters through the supply vents in many of these houses.
Blomsterberg A
A test room with a Displacement Ventilation System was built. Temperature control was provided with a DDC (Direct Digital Control) System, controlling the air volume and the air inlet temperature.
Prochaska V, Schreiber A, Kegel B
Kitchen hoods are frequently found in Belgian kitchens. Most of them have as only function intensive ventilation during certain cooking activities.
Wouters P, Geerinckx B, Vandaele L
The use of indoor carbon dioxide levels is a good method for controlling indoor air quality in office buildings.
Donnini G, Haghighat F, Van Hiep Nguyen
We describe the use of constant injection and pulse injection techniques for measurement of airflow in a duct. Tracer-gas measurements were compared with measurements made using a pitot tube and a hot-wire anemometer.
Riffat S, Cheong K, Holmes M
Knowledge of air movement within a building is often a condition for solving problems with the spread of pollution.
Kvisgaard B, Schmidt L
A new passive tracer gas method for ventilation measurements is described. The method utilizes passive tracer gas release from aliquid perfluorocarbon compound contained in a glass vial, equipped with a teflon membrane.
Stymne H, Eliasson A
Tracergases provide a way to determine airflows in different situations. In some cases it is the only way to get quantitative information.
Hanlo A R
This paper reports the design, development, calibration and testing of a fast-response, multi-channel tracer gas concentration measuring instrument.
Phillips D, Bragg G, Weckman E
This paper extends the integral mass balance approach to the remaining constant concentration technique.
Axley J
This paper presents a new approach to determine the interzonal airflows of a multizone system using tracer gas measurements.
Guitizad S, Jarausch H, Raatschen W
Sandberg and Skaret differentiate between the terms air change efficiency and ventilation effectiveness.
Brouns C, Waters J
Combined ventilation and heating systems in floors demand extensive investigations about the heat transfer before they could be installed in residential buildings.
Steimle F, Mengede B, Roben J
Simulation models basing on 2-dimensional finite-difference approach were developed for the steady-state and dynamic analyses of the thermal coupling of leakage airflows and building components.
Virtanen M
The computer programs published so far have enabled the calculation of airflows at constant temperatures or of air temperatures at constant airflows.
Klobut K, Tuomaala P, Siren K, Seppanen O

Pages