AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

Access to the publications is free of charge.

Annex 14 -Condensation and Energy- started in April 1987, with a take of meeting in Utrecht, The Netherlands. The annex itself was born after a moisture-workshop in September 1985 at the Laboratory of Building Physics, KULeuven, Belgium.
Hens H
The IEA Annex 18 Demand Controlled Ventilating Systems-(DCV-Systems) with 9 participants are just in the middle of the work.
Mansson L G
What does the designer of a future energy-efficient building ask of the air flow specialist? - Static predictions of air flow patterns and optimization of thermal comfort and indoor air quality at design conditions will not be enough for him.
Moser A
Tracer gas techniques have become widely used to measure the ventilation rates in buildings.
Sherman M
The use of passive perfluorocarbon technique for air flow measurements has been developed and tested. The building and testing of the system took approximately one year. The reproducibility of the analysis was tested during the period.
Sateri J, Jyske P, Majanen A, Seppanen O
This paper describes a set of experiments conducted in a three bedroom house in order to identify the leakage distribution of the building and the air flow rate through the on-purpose designed opening of the interior doors.
Fleury B, Gadilhe A
This paper presents and evaluates a new method, based upon tracer gas techniques, for determining interzonal airflows and effective volumes in a multizone enclosure.
O'Neill P J, Crawford R R
It is particularly important to be aware of the air flow pattern in a building when determining indoor air quality problems or calculating space conditioning loads for energy consumption.
Feustel H E
In order to be validated, the computer programs simulating the air flows in multizone buildings need several measured data sets to be compared with. Such a set was measured on the LESO, a mid-sized administrative building.
Furbringer J M, Compagnon R, Roulet C A, Gadilhe A
The paper describes the development in airflow simulations in rooms.
Nielsen P J
Rising moisture from the ground has caused quite a lot of damage on foundations of Swedish buildings. It is in some constructions possible to prevent this by mechanical ventilation below the floor or below the concrete slab.
Hagentoft C E, Harderup L E
Moisture and mould in buildings have become fairly common problems in Italy, particularly since regulations aimed at energy conservation have been enforced in the seventies.
Aghemo C, Lombardi C, Masoero M
A method is being developed for visualization of air flow with application to the indoor problems of heating, ventilating and air conditioning.
Gottschalk G, Revesz Z, Suter P, Tanner P
During the past decade a multitude of diagnostic procedures associated with the evaluation of air infiltration and air leakage sites have been developed.
Harrje D T, Gadsby K