Improve train tunnels. A dynamical ventilation model.

Train tunnels and subways are an interesting field of ventilation. Trains move air through tunnels at rates of 600 m³/s (over 2 x 10^6 m³ per hour) which is much more than flow rates in buildings. Air pressures can vary up to some 3000 Pa leading to air velocities in the range of 10 to 50 m/s. This can lead to unsafe situations and thermal discomfort. The development of high speed trains causes more concern for better tunnel design. Modern stations often house small shops and restaurants, that require lower air velocities for thermal comfort.

Full-scale measurements of indoor air flow.

Full scale measurements of air flow velocities, temperature, intensity of turbulence and air exchange rate are carried out on two rooms with different types of ventilation located in the department of architecture at Chalmers University of Technology. The measurements have shown that mixed ventilation gives variable mean flow velocities with a high risk of draught as compared to the room provided with displacement ventilation. Air exchange rate for the room with displacement ventilation is obtained from tracer gas monitor by employing decay and constant emission methods.

Experimental study of crack flow with varying pressure differentials.

Existing experimental techniques for calculating air flow through building cracks are usually based upon relationships derived from experimental studies employing relatively simple procedures. Typically, a fixed pressure difference, dP, is established across the crack of interest and then the air flow Q through the crack is determined. Most crack flow equations take the pressure differential dP to be steady-state. In reality, the wind forces which generate much of the driving pressures represent highly fluctuating signals.

A technique for controlling air flow through modified Trombe walls.

This paper describes an experimental investigation into the operation of a modified Trombe wall. The construction has been altered to include a layer of insulation material; two alternative positions for this insulation layer have been considered and tested. Air flow from the top of the Trombe wall has also been enhanced by the inclusion of a low power axial flow fan which was controlled to function dependent on measured temperature in the wall cavity.

Modelling the influence of outdoor pollutants on the indoor air quality in buildings with airflow rate control.

Low emitting building materials have contributed to the reduction of indoor air contaminants, and in many countries gas ranges and gas cookers are rarely used. As a result, in buildings located in urban environments, a considerable part of the contaminants in the indoor air may originate from the outdoor air. In urban areas buildings are exposed to high concentrations of a large number of contaminants, especially during traffic peak hours.

Pages