Results of air quality measurements are presented for a group of low-leakage houses located in Saskatoon, Saskatchewan. A total of 46 houses were tested for formaldehyde, nitrogen dioxide, radon, and humidity levels. The median level of formalde
In response to employee complaints of upper respiratory and eye irritation, formaldehyde air sampling studies were conducted in two different office environments. The first was in a series of temporary modular buildings with construction simi
A microprocessor-controlled, five point, all-teflon sequential air sampling system interfaced to a continuous formaldehyde analyser, the CEA model TGM 555 Air Monitor which uses the pararosaniline colorimetric method was used tomeasure the seaso
The results of our investigations in the Federal Republic of Germany on the Rn-222 and Rn-220 daughter product concentration in dwellings and in the open air are presented. The median Rn-222 concentration indoors was approximately 4 times hig
In Sweden there are two major sources to indoor radon, the building material and radon from uranium rich soils. It is now widely accepted that indoor radon daughter concentration in Sweden, higher than 1000 Bq/m3 is most frequently caused by
In large areas of the Swiss Alps, the high radium content of rocks and soil, which results in high source terms for radon from the ground, may produce considerable indoor levels of radon in dwellings with low air infiltration. During the winter
There are a number of reasons to question whether regulation should be the primary means of dealing with indoor air quality problems. The nature of hypersensitivity to indoor pollutant exposures is such that any practical form of regulation m
The prospective study included two groups, a study group, which had retrofitting of their flats, and a control group not exposed to environmental changes in their homes. The results clearly demonstrated a number of positive effects of the replac
New energy conservation policies in New York State are emerging in response to concerns about poor indoor air quality and related public health risks. The evolution of policy has been away from the promotion of energy conservation without explic
The amount of outdoor air supply required in rooms were no one was smoking and only body odour was pesented was investigated using a climate chamer, under clean room conditions. Ten subjects were confined in the room and five panels outside of the room stated the odour level in the sampled air from theroom when compared to clean air. Experiments were performed in four steps of 5,10, 20 and 30 CMH per person. Room temperature was either 22-23 deg C or 32-33 deg C with a relative humidity of 50-60%. The higher temperature was used to study the influence of body odour in sweat.