Compares the guidelines for indoor air quality and minimum ventilation rates outlined in the DIN 1946 and ASHRAE standards. Discusses air quality-controlled ventilation. Outlines the principles and standards governing both natural ventilation and controlled ventilation with heat recovery in residential buildings.
Ventilation and infiltration rates were measured in eight office buildings using an automated tracer-gas measurement system. The buildings range in size from a two-story building with a floor area of about 2000 m2 to a 15-story office building.
Indoor air pollution is defined, and some of the causes are listed, all of which can be harmful to health. The problem is accentuated by recent insulation measures aimed at economising on energy costs, which lead to a dramatic reduction in natu
A single family residence in St. Paul, Minnesota, constructed in 1957, was retrofitted in 1983. This resulted in approximately 50% reduction in annual heating consumption compared to the average consumption over the previous three years. However, the occupants complained of poor air quality. Measurements indicated that total particulates, CO, CO2, relative humidity, and temperature were at levels of some concern; NO2, radon and formaldehyde concentrations were not significant.
Investigates the effects of five different ventilation strategies on the annual energy consumption for heating and warm water of residential (family) homes. The strategies are: (1) natural ventilation, (2) mechanical ventilation and three forms of exhaust plants. Uses weather data from Portland, Oregon and Great Falls, Montana as examples of very different climatic conditions and heating/cooling requirements. The University of Wisconsin TRNSYS program was used for numerical simulation.
Discusses ventilation requirements to achieve acceptable air quality. In many cases, this would lead to unacceptable energy costs, so instead recommends setting standards for heat-exchanger systems, for filters that can control particulates, hydrocarbons and radon gas, and for details such as flow direction and system maintenance. Also standards for 'pollustat' systems should be encouraged by which four surrogate pollutant levels would be kept below suggested threshold levels in all conditions of building use and occupancy.
The advantages and disadvantages of various ventilation systems have been assessed in Germany over the past four years. The programme covered research in unoccupied test rooms as well as in occupied buildings. Results are presented, and the possibilities and limits for energy saving while meeting comfort requirements are discussed.
In new buildings, the requirements for indoor air quality and energy efficiency cannot be met with natural ventilation. In renovations of existing buildings it is, however, often difficult or uneconomic to install a mechanical system. What is often forgotten is that the conditions for natural ventilation will have changed, even if no alterations are made to the ventilation system.
Describes a new ventilation strategy for retrofitted buildings. The system consists of two units including heat recovery, fan, filter, etc, which are installed in the window openings. They are operated in opposite directions which are periodically reversed. When desired, the unit is stopped and used as an airing panel. In laboratory tests the specified values were achieved. The heat recovery proved so efficient that no air heating was needed even at the lowest temperatures. Some noise and freezing problems were reported.
Some of the problems for designing ventilation systems for retrofitted buildings are presented. Measurements were taken in two public buildings in Helsinki with three ventilation systems of different types. In these two buildings only a balanced mechanical ventilation system seemed to fulfill therequirements for a satisfactory and healthy indoor environment.