The impact of ventilation and airtightness on energy consumption.

The total energy consumption for five detached houses with air change rates of around 3 per hour right after construction, was measured and compared with estimated values, over a three-year period. Air change in the bedrooms was also measured. It was found that the recommended value was only obtained in very tight houses. If two windows are open, the ventilation system is partly short-circuited. A modified exhaust air ventilation system was designed to provide a sufficient air change in the bedroom with a reduced total air changein the house as a whole.

Natural ventilation in the UK and some considerations for energy efficient design.

This paper discusses the potential for achieving an "energy-efficient" ventilation system by improving design procedures for natural ventilation. It considers ventilation requirements and the meaning of the term energy-efficient ventilation. Both of these topics are of fundamental importance to any design procedure. Natural and mechanical ventilation systems are discussed. This is done because natural ventilation is often compared unfavourably with purpose-built mechanical systems. It is argued that such comparisons can be misleading, unless all aspects are considered.

Energy conservation by regulation of the central mechanical ventilation system in high rise buildings: realistic or not?

The investigation was divided into several parts: 1, measurements of a mechanical ventilation system, 2, calculation model for this system, 3, measurements of the air leakage of the facades of a flat and 4, calculation model for this flat.

Efficiency of air-to-air heat exchangers in occupied houses.

The purpose of the project has been to determine the saving in energy obtained in the practical operation of an FTX-system -that is, a fan-controlled supply and exhaust ventilation system with heat recovery - compared to an F-system, which is solely a fancontrolled exhaust system. The investigation, carried out in a terrace-house district in Skellefteg, showed the following savings for the FTX-systems in comparison with the F-systems: in 1-storey houses (81 m², airtightness approx. 1): appr. 1000 kWh/year in 2-storey houses (99.5 m², airtightness approx. 3) : appr. 1250 kWk/year.

An economic assessment of some energy conservation measures in housing and other buildings.

Discusses insulation of lofts, roofs, walls, windows and floors, natural ventilation of dwellings and mechanical ventilation with heat recovery in dwellings. Considers cost benefits of weatherstripping and constant-flow ventilators for naturally ventilated houses. Concludes that installation of mechanical ventilation with heat recovery is uneconomic, but adding a heatexchanger to an existing mechanical ventilation system has economic benefits.

Systems of ventilation. Luften mit system.

Discusses how air flow in a building is affected by the position of the ventilation openings in the outside wall. Treats factors determining selection of controlled ventilation system and provides examples of systems available: small air vents, mechanical ventilation with acoustic and thermal insulation, ventilation with heat recovery, etc. Discusses an optimal solution with air quality control.

Long-term monitoring of indoor air quality and controlled ventilation in public buildings.

Long-term monitoring of radon, aerosol and carbon dioxide concentrations was carried out in two Finnish public buildings. In each case, a distinct periodic behaviour of pollutant concentrations was observed. CO2 and aerosol showed maxima during the working hours, but the fluctuations of the aerosol concentration were faster and more irregular. The radon concentration peaked at night and on weekends, dropping off rapidly in the working day mornings when ventilation was turned on.

The sick building syndrome

Examines evidence for relating sickness to the office environment. Notes research into the office building syndrome (obs) in various countries. Notes that although air conditioning goes back to the 1920s, obs has been in the news only during the last five years or so. Notes the contribution to this of energy saving regulations. Notes the complex nature of indoor air contamination. Points to obvious factors such as air conditioning systems unserviced for 30 years, occupational psychology, indoor architecture, climatic constance and air ionisation.

Airtightness and wall construction in prefabricated Swedish single family houses, 1984.

This survey describes how external walls and joints are constructed in practice. The paper gives you an opportunity to compare how successful the implementation of airtightness has been in Sweden in comparison with the results presented in the report D2:1983 "Air infiltration control ..." by A Elmroth and P Levin. The survey covers the majority of all Swedish prefabricated single family houses constructed in 1984. All big prefabrication companies are included in the survey.