Discusses how important it is to understand how the exhaust fan, stack discharge and replacement air contribute to a successful kitchen exhaust system.
Describes how a fully furnished two storey test house was used to perform an experimental study of tracer gas dispersion and airborne moisture movement. The test used two multizone models to simulate the experimental data. States that good agreement was obtained in the comparison and with the tracer gas dispersion. Finds that a representation of adsorption by indoor surfaces must be included in order to accurately model the airborne moisture movement.
The Second Skin Facades can be an useful tool for increasing the efficient use of natural ventilation in order to decrease the energy consumption for ventilation and cooling purposes and to increase the indoor thermal comfort levels. To analyze this type of facades a simulation is set up. The simulation is carried out with the simulation code Simulink.
This work is centered on the transient analysis of natural ventilation provided by a single side opening when only indoor-outdoor temperature differences are present (no wind). Using both simplified "engineering" models and a CFD commercial code (2D), different cases have been examined by varying indoor-outdoor temperature difference, window size, and including or not a heating appliance in the room.
In many cases natural ventilation is used to ensure an acceptable indoor environment. However it is difficult to design a building for acceptable ventilation rates and indoor comfort without the proper tools or guidelines. The passive building simulation tool Building Toolbox was extended with natural ventilation models for the design of natural ventilated buildings. The simulation tool was verified with actual measurements during three case studies to ensure its integrity and to illustrate its applicability in this field.
The wind and buoyancy pressure driving forces for natural ventilation of buildings are very low, typically less than 10 Pa. Depending upon the prevailing climatic and thermal conditions, or even the location of a building on a site in relation to other surrounding buildings and landscape, the predominant pressure force incident on a purpose-provided natural ventilation opening can either be closer to the lower range of pressure differentials (< 2 Pa) or vary over a wider range of higher pressures (2 - 10 Pa).
One sixth of the total energy consumed in Taiwan is for building operation, mainly for summer cooling. The energy consumed for summer cooling can be greatly reduced if naturalventilation can be exerted in Taiwanese urban apartments. To explore the feasibility ofapplying stack ventilation in urban apartments during warm season of Taipei, this studyexamines the ventilation volume induced by the combined wind and stack effect in a twostory building.
This paper describes the wind tunnel study conducted on behalf of the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) to evaluate and quantify the effect of architectural screens on rooftop concentration levels due to effluent from short stacks. An equivalent stack height (ESH) concept is introduced, which is used to develop a stack height reduction (SHR) factor that may be used in conjunction with existing stack design procedures found in the 1997 ASHRAE Handbook-Fundamentals to account for the presence of architectural screens.