Pressurization testing, infiltration reduction and energy savings.

Pressurisation measurements were taken on 55 single family houses immediately before and after house tightening carried out as part of the Modular Retrofit Experiment (MRE) in New Jersey and New York. The data was reduced according totwo pres

The effect of tracer gas on the accuracy of air change measurements in buildings

Compares the air change rates measured using the decay method with several different tracer gases. The tracer gas measurements were conducted in atightly sealed room where constant air leakage rates, ranging from 0.05 to 1 air change per hour could be maintained using an exhaust fan. The tracer gases investigated were CH4, CO, CO2, N2O and SF6. The agreement between tracer gas measurements and measured flow rates of the exhaust fan was very good for CH4, CO and N2O.

Plan and preliminary results of the U.S. Environmental Agency's Indoor Air Monitoring Program - 1982

The U.S. EPA initiated an indoor air monitoring program in 1982, concentrating on commercial or public-access buildings (homes for the elderly, schools, and office buildings). Several buildings from each category are sampled over 2-3 day peri

Natural infiltration - tracer gas test Infiltration naturelle - test au gaz traceur

Provides the results of tests into tracer gas concentration decay carried out in 15 Belgian apartments (Concours CHT) in 1982 to determine the rates of air infiltration. The tests formed part of a research programme which included pressurisation

Ventilation in industrial buildings. Final report

The problems associated with the measurement of ventilation rates and air movement patterns in large single cell buildings which were unoccupied and unheated were investigated using the tracer gases nitrous oxide and sulphur hexafluoride. 

Methods for measurement of air flow rates in ventilation systems

Presents methods for the measurement of air flow rates, including methods for measuring flow in ducts, at exhaust and supply air devices and for air change rates for using tracer gas.

The effect of turbulent wind on ventilation

Shows the results of a study of the effects of turbulence upon ventilation. Controlled fluctuating air flows were directed upon openings in the side of acube simulating a building. The relationship between the turbulent characteristics of the air flow and the ventilation rate in the building modeare examined. Mean windspeed and the turbulent velocity and intensity of the air flow were measured with a thermocoupled anemometer. Resulting ventilation rates were measured by means of tracer gas decay, using CO2 as the tracer and an infra red analyser to monitor the decrease in concentration.

Continuous measurement of air change rate in occupied buildings Boligers luftskifte l brugstilstand

The Department of Building Technology, the Technological Institute of Copenhagen, have for several years been developing equipment for continuous measurement of air infiltration. It enables continuous measurement of air change rate in up to ten rooms, the constant concentration method with tracer gas is used, and the results are recorded on a computer diskette during measurement. Analysis of possible measuring errors show that the method is accurate and to within plus or minus 5%. Shows the results of measurement of air infiltration in 10 relatively airtight dwellings.

Different tracer gas methods for assessing air quality - compilation of experimental data.

Continues on from a previous paper, which gives a theoretical framework for using moments of concentration histories as a means of assessing air quality. Gives a more detailed presentation of the test conditions and the results from each test, together with plots of concentration v.time graphs.