Ventilation systems.

Occupant satisfaction and ventilation strategy - a case study of 20 public buildings.

Occupant response in a good indicator of the effectiveness of a ventilation system. In a one-year study in the province of Quebec region, 20 public buildings were studied. Occupants were asked to answer questions on their perception of their environment and the ventilation at their workstation. Annual energy consumption for each building was recorded. The ventilation systems were studied as well as their rates; minimum outdoor air rates and average total air rates, at each workstation and at the ventilation system. Ventilation rates were plotted against energy consumption.

Design tool for optimizing the selection of ventilation plants.

The main goals for this design tool are: - A powerful, but simple to use, technical and economic tool for selecting a ventilation plant. - Guide and control the consultants in accordance with the owner's economic preferences. - The long run extra cost, if one is forced not to follow the guidelines of the method is calculated in order to get the economic backgrounds for a decision. - Creating a key-value for the cost of ventilation that can be understood by engineers and people with economic education. The three most important parts of the selection of this design tool are: 1.

A suggested standard methodology for the assessment of the performance of domestic ventilation systems.

The monitoring of the performance of domestic ventilation systems is quite a complex exercise. A wide variety of parameters must be taken into account in order that a suitable assessment of performance may be made - in many cases, insufficient data is collected. Even when the data has been collected, it is often the case that comparison of results from different studies is made very difficult due to variations in the treatment and presentation of the data.

Volume control of fans to reduce the energy demand of ventilation systems.

The fan and the ductnetwork is designed for 100% ventilation rate. Because the fan energy is the main important energy consumption in systems all over the year it is worthwhile to control the systems correctly. By reducing the air volume rate the pressure drop in the ductnetwork drops nearly with the second power.

Ventilation by the windows in classrooms: a case study.

Four classrooms of two secondary schools located around Lyon in France have been monitored. The objectives are to analyse the quality of the indoor air and the thermal comfort and also the behaviour of the occupants towards opening of the windows. This paper briefly describes the context and the nature of the monitoring campaign, and presents the results of the measurements with direct interpretation of the ventilation needs.

Improvement of domestic ventilation systems.

The aim of the study was to identify methods for the renovation of ventilation systems in domestic buildings which are 3 - 8 storeys high. Three typical buildings were selected and the problems in ventilation were examined. The designers made their proposals for repairs and the research team analyzed the solutions and made improvements. The special problems compared with new buildings included less airtight building envelopes and leakages in existing ventilation ducts.

High quality ventilation systems - a tool to reduce SBS symptoms.

The present case study refers to a larger office building in Sweden. The employees in this building, which was built in 1982, began to complain about the indoor environment around 1985-86. A preliminary examination of the building started in 1989. The preliminary investigation showed that the concrete framed floors were levelled off with self levelling compound containing casein and that there were relatively high concentrations of ammonia under the PVC-flooring.