Outbreaks of Sick Building Syndrome (SBS) first gained attention in the 1970s in the USA, with thedevelopment of more energy-efficient buildings that depend on mechanical ventilation systems tocirculate fresh air, as well as to control air temperature and sometimes humidity.SBS at office building and so on is not such a severe problem, but, a similar syndrome has beenrecently reported with increasing frequency in airtight new houses in Japan, that is, Sick HouseSyndrome (SHS). We have conducted the survey concerning SHS in Fukushima city, northeast area ofJapan since 2003.
Application of night cooling to educational buildings looks very promising in mild climates. Night coolingstrategy performance in a school building to be realised in Italy during 2008 has been studied by meansof a commercial CFD code.Due to the symmetry of the building, first a 2D numerical model consisting of a vertical section throughthe three-storey building has been developed. The CFD model includes the solid zone describing theconcrete structure.
The energy penalty associated with the conditioning of large quantities of outdoor air in hot and humidclimates is well known. The problem is even more challenging when the application involved requires100% outdoor air. This is the case in an animal care facility, which houses different species ofanimals that are used for laboratory experiments in the field of life sciences. In such cases, it iscrucial that energy conserving HVAC systems be explored.
Using a passive tracer gas technique, 1 and 2 week averages of local mean ages of air have beenestimated in an occupied detached single family house in mid-Sweden during one year. In this paperthe measurement result is compared with the result of transient simulation of ventilation using theCONTAM program. The simulation shows that the whole-house air change rate is dominated by theinfiltration due to mechanically created pressure difference as long as the outdoor temperaturedifference exceeds approx. 10 C.
The growth of automobile population in Kuala Lumpur is an important issue for car parking spacesespecially commercial buildings. The large multi storey and underground car parks seem to offer goodsolution nowadays. Undeniably, indoor air quality (IAQ) is a vital element in the underground car park. Itis so important due to its effects to the human beings.
The effectiveness of natural ventilation, i.e. its ability to ensure indoor air quality and passive cooling ina building, depends greatly on the design process.
To reduce the concentration of volatile organic compounds (VOCs) and formaldehyde emitted frombuilding materials and furnishings, it has been suggested that new buildings undergo a bake-out.According to the existing studies [3, 4], ventilation during a bake-out is believed to be essential forreducing the concentration of indoor air pollutants. For a practical use of bake-out, several ventilationstrategies such as natural and mechanical ventilation can be considered.
A floor heating, so called ‘Ondol’, is widely used in korea, and it has been known that Ondol provids good thermal environment. [1] However, the impact sound through floor is great and ventilation rate depends on infiltration in rooms where the Ondol is a
The indoor air quality management of the railroad passenger cabin is a hot environmental issue inmany countries. Especially, particulate matters are known to be harmful for lung and bronchus, andhigh concentration of carbon dioxide may cause headache and dizziness. Therefore, new regulation tolimit the particulate matters and carbon dioxide concentrations in the railroad passenger cabin is underpreparation in Korea. In this study, a new concept of an integrated novel air cleaning system for railroadpassenger cabin was suggested.
In order to facilitate rational development on the efficient new ventilation system with new detectorsagainst the health problems caused by VOC in residential buildings, authors studied to clarify the actualIAQ conditions around occupied area. To grasp the contemporary circumstances andtransfer-mechanisms of VOC in houses, the actual data regarding the pollutants and its movementwere collected in 9 detached houses in Tochigi prefecture. In this paper, investigated results for indoorthermal environment, ventilation and indoor chemical pollutants are described.