Harrje D.T.
Year:
1981
Bibliographic info:
ASHRAE Journal, March 1981 p.39-41

Discusses use of an instrumented energy audit, as opposed to a walk-through audit. Describes use of the audit to pinpoint infiltration sites. Method used is to depressurize a building and use thermography to locate air leaks. Briefly describes equipment and gives example of an instrumented audit of a residential building. States advantage of instrumented audit is that it gives a quantitative energy analysis as opposed to a qualitative one.