Xiaofeng Zheng, Edward Cooper, Joe Mazzon, Ian Wallis, Christopher J Wood
Year:
2017
Languages: English | Pages: 10 pp
Bibliographic info:
38th AIVC Conference "Ventilating healthy low-energy buildings", Nottingham, UK, 13-14 September 2017

This paper introduces a comparison study of measuring the airtightness of a house sized test chamber using the novel pulse technique and the standard blower door method in a controlled environment. Eight different testing plates have been applied to the improvised envelope of the chamber to establish different leakage characteristics. Each testing plate has a unique opening in the centre of the plate, achieved by obtaining a different combination of shape and thickness of the opening. By using the controlled environment, the vagaries of the natural condition when testing within buildings have been reduced providing a more robust testing environment. This investigation focuses on how the air leakage rate calculated from the measurements made by both techniques compare with each other. Comparable results (±3%) under most scenarios have been obtained. Additionally, other aspects such as usability of the equipment used for the pulse testing have also been appraised.