The air exchange rate and total heat loss were measured in 11 detached dwellings to find the relationship between measured and calculated transmission heat loss factors based on standard Norwegian calculation methods. For 9 houses the measurements were done under stable climatic conditions. Air change rate varied between 0.2 and 0.7 ach with an average value of 0.45 ach. These measurements, together with several others, confirm that the Norwegian Standard (NS3031) for calculation of the transmission heat losses is reasonably correct.
Distribution of energy consumption field measurement in 11 detached dwellings of the same design.