Lundqvist G R
Year:
1985
Bibliographic info:
6th AIVC Conference "Ventilation Strategies and Measurement Techniques" Southern Netherlands, 16-19 September 1985

Natural ventilation rates in bedrooms at night have been measured in retrofitted apartments. The measurements indicate clearly that air quality in bedrooms may be unacceptable in dwellings with an energy-efficient minimal ventilation rate. The air supply rates may be as low as 1 l/s/person in themedian case of bedroom size, ventilation rate and two occupants. The carbon dioxide concentration will reach a level of 4000-4500 ppm in the morning depending on the length of sleeping time in a closed room. The air humidity will have increased too, but depending on the accumulation and condensation of moisture in the room. However, user habits can increase ventilation rates in practice.