Discusses ways of increasing accuracy and thoroughness of energy audits of buildings by use of specialized instruments and improved audit techniques. States air infiltration measurements are key item in audit procedure. Describes 'house doctor' kitwhich with records of past energy usage, knowledge of prevailing weather and a questionnaire are used to establish the energy signature of a house. The kit includes blower door, infrared camera, temperature probes and appliance consumption meter. Describes simple tracer gas method using sulphur hexafluoride collected in sample bottles. Discusses development and use of kit which can be used by homeowners with minimal training
Instrumenting energy audits.
Year:
1979
Bibliographic info:
Princeton University, Center for Environmental Studies Report PU/CEES 91 #DATE 01:07:1979 in English