Presents various measurement and inspection techniques for assessing the thermal performance of the exterior envelopes of buildings. Inspection techniques include the use of ground-based infra-red thermographic surveys, aerial infra-red surveys, tracer gas air infiltration measurements, pressurization tests for measuring the tightness of the building envelope, and spot radiometer surveys for detecting gross defects. Also considers heat flow meters, a portable calorimeter and a microprocessor-driven envelope testing unit. Provides recommended procedures for each technique. They include equipment requirements, conditions under which the techniques can be carried out, calibration, accuracy and limits.
Measurement methods for evaluation of thermal integrity of building envelopes.
Year:
1982
Bibliographic info:
NBS Report NBSIR 82-2605 Nov.1982 127pp. #DATE 01:11:1982 in English