Lidwell O.M. Lovelock J.F.
Year:
1946
Bibliographic info:
Jnl of Hygiene vol 44 p326-332

Describes method of estimating ventilation rate using organic vapours as tracer gases and ultra-violet absorption to measure concentration. Gives table of absorption of different vapours. Suggests estimation using a test paper. This method is less precise but requires a minimum of apparatus.