Kvisgaard B.
Year:
1985
Bibliographic info:
Summary of the project research on fresh-air change rate:1. Copenhagen: Building Technology, Technological Institute, 1985. 7p. 6 figs, 1 ref. #DATE 00:00:1985 in English and Air Infiltration Review, August 1985, Vol 6, No 4,p1-3

This paper presents the measurement technique and results of 23 one-week measurements of air change rate in occupied dwellings. The measurements conducted show that the occupants exert a very considerable influence on the total air change rate. The air change rate for occupied dwellings is, on average, 3-4 times greater than the rate in sealed dwellings (with air-escape valves, doors, windows and ventilation system closed). The measurements also reveal a trend towards a higher air change rate in mechanically ventilated dwellings than in naturally ventilated dwellings.