AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

The AIVC website includes a protected content feature that provides access to AIRBASE. Access to the protected content is free of charge but requires you to register first.


 
In Mediterranean regions, characterized by a hot and humid climate during summer, the exposure of facades and the position of opening windows are important parameters to enhance passive cooling in the building using buoyancy-driven airflow.
M. Coppi, A. Quintino and F. Salata
On the basis of modelling with similarity theory and by using the Archimedes number, Ar, as the similitude parameter, this paper analyzes the air distribution of a busbar corridor in a hydropower station by using the Particle Image Velocimetry (PI
Angui Li, Pengfei Tao, Xin Bao and Yujiao Zhao
Mittels Messungen wird die Luftdichtheit unterschiedlicher Andichtungen an Holzbalken untersucht und es werden Empfehlungen gegeben. Die Luftdichtheit von OSB-Platten wird geprüft und deren Eignung als luftdichte Ebene diskutiert.  
Søren Peper, Armin Bangert, Waldemar Rupps und Zeno Bastian
           
Rechtsanwältin Elke Schmitz, Rechtsanwältin Ulrike Kohls
Praxisbericht der energetischen Modernisierung eines Gründerzeit-Mehrfamilienhauses in Holzbauweise. Dabei wurde der Passivhaus-Standard im Altbau angestrebt (EnerPHit).
Friedemann Stelzer
Nach der Wohnungslüftungsnorm DIN 1946-6 wird die über die Heizperiode gemittelte Infiltrations-Exfiltrations-Luftwechselrate aus der Luftwechselrate bei 50 Pascal (n50) abgeschätzt.
Joachim Zeller
With the increasing need for higher energy efficiency in buildings, airtightness and ventilation systems choice become major performance issues in well insulated buildings.
F. Richieri, B. Moujalled, D. Samri, M. Bourdassol, F.R. Carrié
Die Luftdurchlässigkeitsmessung, inklusive ihrer hohen Anforderungen bei MINERGIE-P- und MINERGIE-A-Gebäuden, kann aufgrund dieser Untersuchung durchaus als sinnvolles Instrument im Bauprozess und deren Erfüllung als langfristiges Qualitätsmerkmal
Beda Bossard und Urs-Peter Menti
Legislative drivers and new research with demonstrated energy impact on the importance of building and ductwork airtightness are leading to increased activity in this aspect of building energy performance.
F. R. Carrié, M. Kapsalaki and P. Wouters
Unter Qualität versteht man die Güte aller Eigenschaften eines Objektes, Systems oder Prozesses. Somit beschäftigt sich die Qualitätssicherung also mit der Bewertung und Einhaltung beschriebener bzw. vertraglich zugesicherter Eigen-schaften.
Benjamin Standecker
Im aktuellen Entwurf der EnEV 20141 wird gefordert, dass bei Luftdurchlässigkeitsprüfung des Gebäudes das Verfahren B der DIN EN 13829:2001-022 verwendet werden muss.
O. Solcher
Mit dem Amortisationstrainer, einer intuitiv zu bedienenden EXCEL®-Anwendung, können Energie-kosten transparent berechnet und als kumulierte jährliche Gesamtkosten inklusive der Investitions-kosten (mit/ohne Darlehensanspruch) grafisch dargestellt
Wilfried Walther
Das BUILDAIR-Symposium, die Tagung zum Thema Gebäude-Luftdichtheit, feiert 20-jähriges Jubi-läum.
Wilfried Walther
Der Einsatz von Fensterfalzlüftern zur Sicherstellung der Minimallüftung ist vor allem in der Bestandssanierung ein Thema.
Michael Mahler
Während für neu zu errichtende Gebäude Anforderungen an die Luftdichtheit und Hinweise zur Planung und Ausführung der luftdichtenden Ebene in Verordnungen und Normen hinreichend dokumentiert sind, ist dies für bestehende Gebäude nicht der Fall.
Liane Vogel
Aktuell werden viele Dächer im Bestand saniert, wobei meist Dichtungsbahnen in „Sub- top- Verlegung“ von außen nachgerüstet oder Auf- Sparren- Dämmsysteme verwendet werden.
Thomas Runzheimer