Reduction in air leakage rates due to weatherization of homes can be determined by fan pressurization and tracer gas techniques, but only the latter gives the results under normal occupancy conditions. Assessment of such rates measured before and after weatherization must consider their dependence on wind speeds and inside-outside temperature differences.
The manufacturing procedures and performance of a building air infiltration kit consisting of miniature passive perfluorocarbon tracer permeation sources and passive adsorption tube samplers are described.
Facts and ideas are presented to improve cost effective designs for airtightness and ventilation systems. Schematically alternative measures to save energy are presented. An investigation of the rate of ventilation in 25occupied houses is described, using pressurization, tracer gas and measurements of air flow through exhaust air terminal devices. At a mechanical ventilation rate of 0.25 ach, the measured total ventilation rate averaged 0.29 ach (minimum 0.12 and maximum 0.50). Further results are given for 5 more recently constructed houses.
Reviews the most important sources of indoor air pollutants, and means of measuring the contamination of room air by persons (carbon dioxide and odours). Lists some recommendations for minimum ventilation rates, based on the results of experimental investigations.
This paper presents the measurement technique and results of 23 one-week measurements of air change rate in occupied dwellings. The measurements conducted show that the occupants exert a very considerable influence on the total air change rate. The air change rate for occupied dwellings is, on average, 3-4 times greater than the rate in sealed dwellings (with air-escape valves, doors, windows and ventilation system closed). The measurements also reveal a trend towards a higher air change rate in mechanically ventilated dwellings than in naturally ventilated dwellings.
A steady state multi-cell calculation model has been developed in order to predict the interconnection between airtightness and ventilation rates. The model has been tested with measured leakage data of a detached house.
Ventilation and air exchange in buildings and industrial plants can be induced by external winds and by buoyancy forces. The dependence of the air exchange and heat transfer on a large number of factors, including the detailed configuration of the building and surroundings makes an analytical or numerical analysis of practical design problems impractical, particularly when both the buoyancy and the wind-induced pressures are of the same order of magnitude.
The total energy consumption for five detached houses with air change rates of around 3 per hour right after construction, was measured and compared with estimated values, over a three-year period. Air change in the bedrooms was also measured. It was found that the recommended value was only obtained in very tight houses. If two windows are open, the ventilation system is partly short-circuited. A modified exhaust air ventilation system was designed to provide a sufficient air change in the bedroom with a reduced total air changein the house as a whole.
Ventilation requirements for the reduction of humidity. Required air change rates for hygiene and moisture removal for various rooms are given. Air flow rates are calculated for natural ventilation with closed windows, hopper windows and controlled ventilation. Ventilation by window opening is discussed. Gives examples of the transfer of moisture within a building, and the main reasons for ventilation, with particular emphasis on moisture removal. Lists danger of condensation on various building elements, causes and remedies. Advises on ventilation measures.
In the weatherization of building structures to minimize convective heat loss, the air exchange rate is reduced. Pollutants of indoor origin are retained near the occupants. Further, outdoor pollutants may be concentrated indoors under partic