Air change rate measurements in the Roulet villa at Apples. Mesure du taux de renouvellement d'air dans la villa Roulet a Apples.

The air change rate and the volume of heated air of the villa were measured by the constant concentration tracer gas method during a period of 11 days. The total volume of the villa is 1000 m3 and the heated volume 530 m3. It is built on six half-levels. The occupants continued their normal lifestyle during themeasurements. The Compact Equipment for Survey of Air Renewal (CESAR) was used with nitrous oxide as tracer gas at a concentration of 100 ppm. The mean global air change rate was 0.50/h.

Energy use, infiltration, and indoor air quality in tight, well-insulated residences.

Two bi-level houses in Gaithersburg, Maryland, USA, of identical design and construction were studied to determine the relationships among air exchange, energy consumption, and indoor pollutants. The experimental house was retrofitted and equip

Radon transport into a detached one-story house with a basement.

Describes a five month study which measured radon concentration, air exchange (ventilation) rate, weather and radon source parameters in a house near Chicago. Factors influencing radon entry rate were investigated. Discusses the measurements presented, noting some patterns in the data which are hard to explain. Applies two models for radon entry rate to high and low airborne alpha activity at the sump.

Mechanical ventilation system requirements and measured results for homes constructed under the R-2000 super energy-efficient home program.

The R-2000 Super Energy-Efficient Home Program is a cooperative industry/government initiative sponsored by Energy, Mines and Resources Canada (EMR) and delivered by the Canadian Home Builders Association. The program supports building industry development, training of builders and the construction of energy-efficient houses incorporating high levels of insulation, a well sealed air barrier and mechanical ventilati on systems with heat recovery. In 1983, with assistance from the Buildings Energy Conservation Sub-Committee (B.E.C.S.

Air exchange rates based upon individual room and single cell measurements.

For more than two years a series of detailed air infiltration measurements have been conducted over the complete yearly weather cycle on two identical side-by-side test houses in Gaithersburg, Maryland, USA. These measurements have been part of a broad study of the interaction of air infiltration , indoor air quality and energy in tightly constructed, well-insulated homes. The standard method of collecting air infiltration data throughout the study has been tracer gas decay. Operation of the duct air circulation fans has transformed each house into a single well-mixed cell .

Effect of unvented combustion appliances on air exchange among indoor spaces.

The effects of operating unvented appl i ances and opening windows on indoor pollutant levels and air exchange rates are being studied under the sponsorship of the Gas Research Institute. The study is being conducted i n an instrumented, well-characterized bilevel house located near Washington, D.C. Air leakage due to window openings is characterized by pressurization measurements and the air exchange increment is characterized through tracer gas measurements. Two unvented space heaters, one radiant and the other convective, are operated singly and in combination with a gas cooking range.

Ventilation research and characterization in three types of residences.

Pacific Power and Light Company and Battelle PNW Laboratories have completed a project which investigated residential ventilation rates. The results presented in the report discuss evaluation of methods used to measure ventilation rates, the behavior of ventilation rates in residences and the comparison of ventilation rates among home construction types. The perfluorocarbon tracer gas decay technique for measuring ventilation rates was concluded to be the best method used during the testing.

Use of a single tracer gas for measurement of ventilation rates in a large enclosure.

This paper describes a preliminary investigation of the validity of a means of calculating the ventilation rate of a large enclosure from experimental data. It was assumed that the air in the enclosure is not perfectly mixed. The measurement method selected was tracer gas concentration decay. Thecalculation of ventilation rate was performed by "least squares" fitting of a model to the observed tracer gas concentrations. Simulations of tracer gas concentration decay measurements were performed with varying initial distribution of tracer gas.

Monitoring of ventilation and humidity in crawl spaces of dwellings.

Several physical phenomena which may contribute to moisture migration from the crawl space to the living spaces in houses are outlined. Results of two projects to monitor moisture migration are presented.