Interlaboratory comparison of passive samplers for organic vapours with respect to their applicability to indoor air pollution monitoring: a pilot study.

This document reports on analytical work carried out in cooperation among three European laboratories. The purpose of this work was to carry out a first assessment on the performances of passive samplers for organic vapours when used in indoor air pollution monitoring and simultaneously to evaluate theinterlaboratory agreement on low concentration analysis of a variety of volatile organic compounds. Two types of passive samplers were thus exposed in the different facilities and replicate specimens were analysed at each of the three laboratories.

Quantitative determination of formaldehyde in air using the acetylacetone method.

The quantitative determination of formaldehyde in air using the fluorimetric acetylacetone method is described. Known concentrations of formaldehyde were generated and collected in water using absorbers. The sampling rate was 0.5 l/min, and the sampling volumes varied from 2 to 20 l, depending on theconcentration level. Under these conditions the entire sampling and the analytical method were evaluated over a range of 0.2-1.7 mg formaldehyde per m3 of air.

Indoor air pollution due to organic gases and vapours of solvents in building materials.

The emission of organic gases and vapours of solvent type from 42 commonly used building materials was measured under standard atmospheric conditions. 

Indoor air quality: is my home healthy for me?

Gives basic facts about indoor air pollution for homeowners. Lists common indoor air pollutants and guidelines for generally acceptable levels of selected air contaminants. Some suppliers of measurement equipment are mentioned.

Mechanical ventilation system requirements and measured results for homes constructed under the R-2000 super energy-efficient home program.

The R-2000 Super Energy-Efficient Home Program is a cooperative industry/government initiative sponsored by Energy, Mines and Resources Canada (EMR) and delivered by the Canadian Home Builders Association. The program supports building industry development, training of builders and the construction of energy-efficient houses incorporating high levels of insulation, a well sealed air barrier and mechanical ventilati on systems with heat recovery. In 1983, with assistance from the Buildings Energy Conservation Sub-Committee (B.E.C.S.

Effect of unvented combustion appliances on air exchange among indoor spaces.

The effects of operating unvented appl i ances and opening windows on indoor pollutant levels and air exchange rates are being studied under the sponsorship of the Gas Research Institute. The study is being conducted i n an instrumented, well-characterized bilevel house located near Washington, D.C. Air leakage due to window openings is characterized by pressurization measurements and the air exchange increment is characterized through tracer gas measurements. Two unvented space heaters, one radiant and the other convective, are operated singly and in combination with a gas cooking range.

Indoor air quality and air exchange in bedrooms.

Natural ventilation rates in bedrooms at night have been measured in retrofitted apartments. The measurements indicate clearly that air quality in bedrooms may be unacceptable in dwellings with an energy-efficient minimal ventilation rate. The air supply rates may be as low as 1 l/s/person in themedian case of bedroom size, ventilation rate and two occupants. The carbon dioxide concentration will reach a level of 4000-4500 ppm in the morning depending on the length of sleeping time in a closed room.

Advanced energy-efficient ventilation.

It is often stated that advanced ventilation or air conditioning is expensive or energy-wasting. There are, however, several examples of highly energy-efficient air conditioning systems in industrial, commercial and public buildings. Energy-efficiency can be achieved by - optimizing air flows or demand-controlled ventilation - avoiding simultaneous heating and cooling (except if "free") - advanced automatic control system - good operation and maintenance The performance of ventilation and air-conditioning depends on several factors in the building process.

Indoor climate in 6 low energy houses. Indeklimamalinger i seks lavenergihuse.

Over a one-year period, measurements were taken of air temperature, air humidity, ventilation rate, concentration of organic gases and vapours, formaldehyde and odour intensity in a small unfurnished bedroom in each of 6 new unoccupied low energy houses. The indoor climate was on average characterized by an air temperature of 24.7 plus or minus 3 degrees C, and an air humidity of 5.9 plus or minus 2.0 g/kg. Ventilation in each room was between 0.79 and 2.92 air changes per hour. On average 14 different compounds were identified in the samples, a total of 23 compounds being identified.

Pages