A comparative study of the performance of general ventilation systems in evacuating contaminants

Based on the age concept, the performance of the following three principle ventilation schemes have been monitored (supply air terminal - extract air terminal), ceiling-ceiling, ceiling-floor, floor-ceiling. All systems used only air for both heating and cooling. Contaminants with both greater, less and approximately the same density as air were released at a point source. The tests were both carried out in an empty room and with a person (heated mannekin) in the room.

Contaminant removal performance in terms of ventilation effectiveness.

The paper shows that age analysing techniques are an excellent tool to assess ventilation effectiveness. It is important to differentiate between air exchange effectiveness and contaminant removal effectiveness, having continuous generation of contaminants. Only when a source is homogeneous andpassive, are the age of the air and the contaminants in the room equal. However, the air exchange effectiveness accounts for the removal effectiveness of the contaminant left in the room when the generation stops.

The sick building syndrome

Examines evidence for relating sickness to the office environment. Notes research into the office building syndrome (obs) in various countries. Notes that although air conditioning goes back to the 1920s, obs has been in the news only during the last five years or so. Notes the contribution to this of energy saving regulations. Notes the complex nature of indoor air contamination. Points to obvious factors such as air conditioning systems unserviced for 30 years, occupational psychology, indoor architecture, climatic constance and air ionisation.

The multi-chamber theory reconsidered from the viewpoint of air quality studies.

A general multi-chamber model is presented and explored from the viewpoint of air quality studies. The model involves the following key concepts: purging flow rate and age distribution of both air and contaminants. From the physical and mathematical properties of the model, are deduced estimates of themagnitude of, and the relations between, the key concepts. The practical use of the model is illustrated.

Indoor air quality. 20 existing homes.

Complaints related to moisture problems in houses which had been air sealed, led to a study of indoor air quality in 20 weatherized demonstration homes in the Cambridge, Ontario area. 

Indoor radon concentrations in public buildings

Indoor radon concentrations have been measured in a 13 year old two story concrete building of the University of Texas at Dallas. Variations of the radon concentration from the basement to the second floor in offices, classrooms, laboratories, storage rooms, corridors and other locations have been measured. Dependence of the above concentrations on the location and ventilation rates have been studied.

Air-to-air heat exchangers for energy efficient ventilation of "tight" structures.

Reducing the air change rate of a house increases the concentration of pollutants in the indoor air. These pollutants are identified and located within the residential structure. Air-to-air heat exchangers are suggested tocontrol ventilation, and the three basic types described.

Window-opening behaviour in office buildings

In countries such as the United Kingdom that possess a temperate climate, the majority of buildings are not air-conditioned but depend upon natural ventilation and relatively simple heating systems. Openable windows are used to reduce the in

Field survey of indoor air pollution in residences with suspected combustion related sources

Thirty residences were monitored for nitrogen dioxide, carbon monoxide, formaldehyde, respirable suspended particles, and air exchange rate for forty-one one-week periods using integrating samplers. The residences were located in the northwest a

Continuous monitoring in occupied residences of air contaminants from unvented combustion sources

Continuous monitoring of NO, NO2, CO, CO2, and O2 depletion was conducted in 14 residences (13 with kerosene space heaters and one without) in two locations in the residence (room with the heater and bedroom) and outdoors. The continuous monitor