Study on ventilation performance and indoor air quality of a portable classroom: field measurement and numerical simulation.

This paper describes an investigation into the ventilation performance and the indoor air quality of a portable classroom. Both field measurements and numerical simulations based on CFD (Computational Fluid Dynamics) technology were used. Field measurements in an unoccupied classroom used smoke to visualize the flow pattern, and hot-film probes to quantitatively measure air velocity. These field measurements provided the boundary conditions for CFD simulations and the experimental data to examine the accuracy of the CFD simulations.

The neutral height in a room with displacement ventilation.

This paper investigates the relationship between the neutral height for air distribution and the ventilation load in a room with displacement ventilation. An environmental chamber equipped with a displacement ventilation system has been used to carry out the neutral height measurements with the presence of a heated mannequin and other heat sources in the chamber. The total room load used was varied from 104 W to 502 W, i.e., corresponding to a ventilation load from 10 W/m2 to 60 W/m2. The prediction of the neutral height was based on plume theory.

Advances in natural ventilation design procedures.

A number of new techniques have been developed in recent years, by various researchers, to assist in the sizing and positioning of natural ventilation openings. These may be of considerable assistance in the natural ventilation design process, while still allowing architectural freedom. This paper reviews some of the available techniques. The complexity of the configurations accounted for by the procedures ranges from two openings with the indoor air at a uniform temperature to a technique that allows for multiple openings throughout a multi-zone structure.

Experimental and numerical prediction of indoor air quality.

This paper is based on a dual approach (experimental and numerical) in order to predict the indoor air quality for small ventilated enclosures. The experimental part employs a ventilated test room and a tracer gas technique (constant method as gas injection) to estimate the diffusion of a pollutant. The gas used is the sulphur hexafluoride (F6S). The numerical approach is a CFD simulation, adding a convection - diffusion equation (to determine the local mass fraction of the pollutant) to the equations normally used to solve a turbulent flow.

Emissions of VOCs from building materials and the indoor air quality of a new naturally ventilated office building.

This study investigated the sources and concentrations of volatile organic compounds (VOCs) including formaldehyde in the air of a new office and conference centre building. The building is naturally ventilated, and was designed to demonstrate a number of innovative approaches to environmental design. Occupant surveys have shown a high level of occupant satisfaction with the indoor environment.

The air quality at the breathing zone with displacement ventilation.

This paper presents the difference in the air quality between that perceived by the occupants (breathing zone) and that in the occupied zone as a whole. An environmental chamber with displacement ventilation system has been used to carry out the measurements with the presence of a heated mannequin and other heat sources. Measurements of the age of air distribution, the air exchange index and the ventilation effectiveness were carried out at different points in the chamber for different room loads.

Evaluating aircraft air cabin quality.

             

US hotel with good IAQ leaves you breathing easy.

            

Pages