The second of two sections of a report of air change measurements in the winter period 1975/76 of non-air conditioned buildings in Switzerland, chiefly dwellings. Recapitulates the reasons for the research, the theoretical bases, measurement method used and aims of the experimental investigations. Sets outin tables detailed results of measurements carried out in a wide range of Swiss dwellings of different ages, locations, construction, design and type.
States that the reduction in energy losses due to reduced air infiltration is often overestimated because the effect of open windows is not taken into account.< Shows that the habits of airing are rather similar in some European countries. The proportion of windows open or ajar is inversely proportional to the indoor- outdoor air temeperature difference over a large interval of this temperature difference.< The proportionality constant seems to take a value that is independent of the building construction or the heating system of the residential building.
Provides a summary of Report IIIb of the overall research project `air change in buildings' undertaken by the EMPA, Switzerland, sponsored by the Swiss Federal Ministry for Environmental Protection. Describes an investigation into the frequency and duration of window ventilation over an entire heating season by the occupants of 32 flats. Treats the two blocks of flats investigated, the results of questionnaire circulated to the occupants concerning ventilation habits, the measurement and observation methods applied, and the evaluation methods applied to the data obtained.
Provides a summary of Report IIIc of the overall research project `air change in buildings' undertaken by the EMPA, Switzerland, sponsored by the Swiss Federal Ministry for Environmental Protection. Describes a measurement programme undertaken in an unoccupied single family house built in 1979.
Provides a summary of Report IIIa of the overall research project `air change in buildings' undertaken by the EMPA, Switzerland, sponsored by the Swiss Federal Ministry for Environmental Protection. Describes an investigation ontwo identical insulated flats in the same block with the same orientation, one with folding shutters and the other with roller blinds. The occupants were instructed on how to close the blinds at night. Their normal living habits and ventilation preferences were not affected. Illustrates the flats and blinds diagrammatically and in photographs.
Treats the three main factors contributing to ventilation heat loss- natural air exchange driven by wind pressure and temperature differences, air exchange caused by the user and forced air change under the influence of exhaust air installati
Measurements were made of the apparent volume flows in the mechanical ventilation system of a block of flats, along with the expected energy arising from domestic ventilation. The aim was to see what energy saving could be obtained by reducing the mechanical ventilation in the block of flats. It was found that this depended on the reaction of the occupants. If they opened an extra vent light for a few hours per day, then the energy losses due toventilation were higher then before the reduction of the mechanical ventilation.
Reports survey of indoor climate problems in dwellings. Questionnaires were distributed to 424 families who had complained of indoor climate problems and 240 replies were received. The questionnaires dealt with complaints relating to the dwellings and the age, profession, health and smoking habits of theoccupants. The dwellings are described by type, age, material of outer and interior walls, ceiling and floor. There are questions on ventilating habits, cleaning habits and occupants' views on dust, noise, odour, temperature, humidity and draughts.
Gives results of a survey carried out in December 1978 on heating and ventilating of dwellings. 2000 men and women were questioned throughout the federal republic. Gives range of dwellings, desired and actual room temperatures, types of windows, frequency and duration-of window opening and the existence of draughts.< Concludes inter alia that heat loss through ventilation is greater than commonly assumed. In particular this heat loss is through leaky windows and ventilated bedrooms.
Treats report investigating results of door opening in terms of energy loss and changes to indoor climate. In 3 sections. Treats: 1) general regulations and manufacturing standards and relevant swedish building regulations concerning airtightness, thermal insulation and functional aspects. 2) Flow of air under different conditions such as pressure differences caused by variations in temperatures and wind. 3) Describes laboratory experiments using 1:10 scale fluid model.