Assesses the quality of retrofit work carried out in 329 Swedish houses, which had received government energy-saving funds. Describes the selection of dwellings, the measurement methods employed (including thermography, pressure testing, tracer gas and heat flow) and the results.< In most houses, insulation work in attics and on external walls had been carried out satisfactorily. However, the houses were still not air tight and exhibited high ventilation figures (for pressure tests 8 air exchanges per hour at 50 Pa and for tracer gas tests 0.6 air exchanges per hour). It is probable that defects in the original construction were never corrected.
An investigation of the application of government-supported energy conservation measures. Subreport 2: Results from measurements in the field. Undersokning av hur statligt stodda energisparatgarder utforts.
Year:
1980
Bibliographic info:
Bulletin M80:18 National Swedish Institute for Building Research 64p. #DATE 01:01:1980 in Swedish