AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

The AIVC website includes a protected content feature that provides access to AIRBASE. Access to the protected content is free of charge but requires you to register first.


 
The estimation of low-rise, residential building infiltration rates using envelope airtightness values from whole building fan pressurization tests has been the subject of much interest and research for several decades, constituting a major topic
Andrew Persily, Lisa Ng, W. Stuart Dols, Steven Emmerich , United States of America
In Switzerland, 70 % of building refurbishments are realised in stages. When only a window replacement is done, the new airtight windows can lead to a reduced infiltration air exchange and subsequently there may be moisture issues, e.g. mould.
Caroline Hoffmann, Achim Geissler, Claudia Hauri, Heinrich Huber, Austria
The indoor thermal comfort and air quality in classrooms have become of interest worldwide, predominantly because of their influence on children’s health, learning performance and productivity.
Shamila Haddad, Afroditi Synnefa, Miguel Ángel Padilla Marcos, Riccardo Paolini, Deo Prasad, Mattheos Santamouris, Australia
The association between indoor air quality (IAQ) and sleep quality was investigated in this study.
Chenxi Liao, Marc Delghust, Jelle Laverge, Belgium
The indoor air quality is very important for the well-being of occupants, especially in the case of young babies. This research focuses on the air quality of the surrounding air inside a crib with sleeping infants.
Gert-Jan Braun, Wim Zeiler, Netherlands
A ventilation performance report is mandatory for every new residential building in Flanders, for building permits issued since January, 1st 2016.
Maarten De Strycker, Liesje Van Gelder, Martyna Andrzejewicz, Valérie Leprince, Belgium
The measurement of natural airflows is practically challenging. Driving forces that induce natural airflows are characterized by low pressure differences.
Gabriel Remion, Bassam Moujalled, Mohamed El Mankibi, France
This study aims to evaluate the performances of a VMI, a demand-controlled mechanical supply ventilation system, in an experimental house, in terms of indoor air quality (IAQ), energy performance and thermal comfort.
Clement Laffeter, Xavier Faure, Michele Potard, Claude Bardoul, Julien Escaich, Ophelie Ouvrier Bonnaz, Etienne Wurtz, France
Wood is a hygroscopic material, it has the ability to adsorb or desorb water in response to the ambient relative humidity. Thus, the ambient air will affect the moisture content of the wood, and in turn, the dimension of the wood.
Paula Wahlgren, Fredrik Domhagen, Sweden
Thermal comfort and sensation are important aspects of the building design and indoor climate control as modern man spends most of the day indoors.
Ali Youssef, Nicolás Caballero, Jean-Marie Aerts, Belgium
Due to the wind induced pressure, different results may be obtained if the inside-outside pressure difference is measured across different locations on the building envelope, i.e.
Jiří Novák, Czech Republic
The new schools in Canada are designed to improve indoor environment quality while achieving a much better energy performance than the code compliance requirements.  
Michel Tardif, Sébastien Brideau, Canada
As newer homes are being built tighter than the existing housing stock, questions have been raised about the concentrations of pollutants of concern in new homes and how mechanical ventilation systems can address this issue.
Iain Walker, Brett Singer, Rengie Chan, United States of America
Outdoor air change qualifies the air that enters into the buildings. The outdoor air moves freely along the urban mesh favoured by the wind forces and stresses.
Ángel Padilla-Marcos Miguel, Alberto Meiss, Raquel Gil-Valverde, Irene Poza-Casado, Jesús Feijó-Muñoz, Spain
Building airtightness tests have become very common in several countries, either to comply with minimum requirements of regulations or programs, or to justify input values in calculation methods.
Dimitrios Kraniotis, Arnab Chaudhuri , Norway
Within the ventilation principle of buildings, the outdoor air is considered as a source of fresh, "clean" air.
Joris Van Herreweghe, Samuel Caillou, Tom Haerinck, Johan Van Dessel, Belgium
From a product point of view, today’s state-of-the-art ventilation boxes for residential buildings are generally reliable, efficient and silent according to formal European and national product standards.
Koen Maertens, Belgium
Mixed-mode ventilation uses intelligent switching between natural and (partly) mechanical ventilation modes to find the best possible balance between indoor air quality, user comfort and energy consumption.
Bert Belmans, Dorien Aerts, Stijn Verbeke, Amaryllis Audenaert, Filip Descamps, Belgium
The airtightness of new buildings has significantly improved in the last two decades thanks to building energy performance regulations. However, until now, low knowledge is available about the evolution of buildings’ envelope airtightness.
Andrés Litvak, Fabien Allègre, Bassam Moujalled, Valérie Leprince, France
The work presented is the continuation of the research on the probabilistic modelling of air infiltration carried out by the author over many years.
Krystyna Pietrzyk, Sweden