A study on indoor radon

The results of our investigations in the Federal Republic of Germany on the Rn-222 and Rn-220 daughter product concentration in dwellings and in the open air are presented. The median Rn-222 concentration indoors was approximately 4 times hig

Tracing of radon leakages

In Sweden there are two major sources to indoor radon, the building material and radon from uranium rich soils. It is now widely accepted that indoor radon daughter concentration in Sweden, higher than 1000 Bq/m3 is most frequently caused by

Assessment of additional exposures and risks from airtightening of homes in an Alpine area with high radon emanation

In large areas of the Swiss Alps, the high radium content of rocks and soil, which results in high source terms for radon from the ground, may produce considerable indoor levels of radon in dwellings with low air infiltration. During the winter

Indoor air quality in Canadian homes - Policy, regulatory and consumer education issues

There are a number of reasons to question whether regulation should be the primary means of dealing with indoor air quality problems. The nature of hypersensitivity to indoor pollutant exposures is such that any practical form of regulation m

Moisture problems in houses.

Examines the causes of condensation problems and ways of reducing or eliminating them. Deals with diffusion through the building envelope, mechanical dehumidification and ventilation. Considers condensation inside cavities and roof spaces.

A prospective study of the health and comfort changes among tenants after retrofitting of their flats

The prospective study included two groups, a study group, which had retrofitting of their flats, and a control group not exposed to environmental changes in their homes. The results clearly demonstrated a number of positive effects of the replac

Thermographic identification of building enclosure defects and deficiencies. Canada NRCB Digest 229.

Provides a brief introduction to infrared theory and its application in building analysis, and describes some typical building faults that may be identified by thermographic inspection.

Emerging energy conservation policy and regulatory issues in New York State

New energy conservation policies in New York State are emerging in response to concerns about poor indoor air quality and related public health risks. The evolution of policy has been away from the promotion of energy conservation without explic

The BKL-method - A simplified method to predict energy consumption in buildings

Presents a simplified method for estimating heat consumption in buildings. The basis of the method are presented, along with an example of how to apply it. The method requires climatic data in a specific form and the way to calculate this is also discussed. Finally, gives some comparisons between results from this method and detailed computer simulations.

A CO2-controlled ventilation system.

Describes the CO2-controlled ventilation system of the energy efficient EKONO II office building in Helsinki. An air sample is taken from a main return air duct, pumped to a CO2 analyzer which gives the message of the concentration tothe computer. The computer regulates the opening of the recirculation air and outdoor air dampers to keep the CO2 concentration in return air below a certain level. Shows fluctuation of outdoor air rate and CO2 concentration during one day.

Pages