Airbase

AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

Access to the publications is free of charge.

This paper deals with a CFD simulation of a chilled ceiling in a test chamber. The results demonstrate that a slight non-uniformity in cooling power of the ceiling panels produces a great asymmetry in predicted room airflows.
Bryan J, Booth WB, Topaltziki A, Picha E
Critical parameters such as the particle source location, air supply inlet design, operating table location, and lamp design are responsible for the particle distribution within the operating room, they have been investigated by means of CFD.
Liu Y, Moser A
A wall return and a ceiling return air arrangements of turbulent type clean rooms are presented in this paper. The influences of obstacles on the flow fields are compared by a numerical simulation.
Tung YC, Hu SC
That study aimed at investigating the contaminate distribution in and around a naturally ventilated livestockbuilding with and without an upstream obstacle.
Zhang G, Ikeguchi A, Morsing S, Takai H, Strom JS, Ravn P, Okushima L
Few studies dealing with the effect of displacement ventilation on humidity gradient in a hot and humid region have been made . In this paper it is done with a case-study approach (measurements were made in a factory located in the Tropics).
Kosonen R
That paper presents the results of a thermal comfort evaluation research in a brazilian office building : the measurements show that an underfloor air distribution system can provide comfortable conditions for both sitting and standing occupants
Leite, Brenda CC
A model of an UFAD system in a ventilated room is proposed , the room is ventilated with one heat source and one cooling vent as a two-layer stratification.
Peter Lin YJ, Linden PF
The experiment shows that the temperature and velocity fields generated above a seated person are comparatively better approached by a thermal manikin rather than a cylindrical dummy.
Borges CP, Quintela DA, Brites GN, Gaspar AR, Costa JJ
This study presents a model to predict the time required by a pollutant to disperse in a room, due to the effects of room occupancy (a moving person enhances the mixing of pollutants).
Mora L, Gadgil AJ
Experiment and CFD simulation show the influence of moving person simulator (of cylinder shape) and thermal manikins on air distribution in ventilated rooms.
Matsumoto H, Ly Hai N, Ohba Y
By means of CFD, the results of that study express a significant influence of Computer Simulated Person geometry on local flow pattern and on personal exposure to contaminants released from the floor surface.
Topp C.
This paper proposes a simple mathematical model for calculation of the convective air flow rate induced by humans. That model has been then compared to a more complex one and to experimental data with satisfactory results.
Dokka TH, Tjelflaat PE
This paper investigates the possibilities to create velocity variations of that type : (change from "low" to "high" velocity and then back "low" velocity again) in a whole room using standard velocity components.
Wigö H, Sandberg M
16 segmental and all body heat transfer convective coefficients were determined in tests performed with a thermal mannequin placed in the test chamber of a large wind-tunnel.This paper presents a general table with the numerical coefficients of th
Silva MCG, Coelho JA
The aim of that study is to make a database of the local convective heat transfer coefficients for each part of a human body in sedentary and standing environments through the use of an experimental thermal manikin and an analysis of the radiati
Yang JH, Kato S, Hayashi T, Murakami S
CFD is used to simulate the effects of respiration in displacement ventilated rooms.
Bjorn E.
This paper reports a large-scale investigation result on seat occupancy rate in a typical Japan office with 240 workers. The experiment lasted 3 months.
Nobe T, Tanabe SI, Lee SJ, Tomioka Y
For that study , an heated manikin, in a seated position, is exposed to a local thermo ventilator that promotes a non-uniform horizontal flow ( front , behind and right side) ; an interior climate analyser measures the environmental variables
Conceiçao EZE, Lucio MJR
The authors introduce a new airflow characteristic, the equivalent frequency, as an integral measure for the frequency of the random velocity fluctuations in rooms.
Zhou G, Melikov AK, Fanger PO
For that study, 40 subjects were exposed to controlled air movements ( slightly cool, neutral, slightly warm thermal sensations at 18 °C, 20°C, 23°C, 26°C and 28°C). Their responses were collected.
Toftum J, Melikov A, Tynel A, Bruzda M, Fanger PO

Pages